Network Audio Adapter NX-100, NX-100S Firmware Ver.2.15
                                            February 5, 2007
============================================================

ReadMe File

Thank you for downloading the TOA Network Audio Adapter 
NX-100, NX-100S Firmware Ver.2.15.

The NX-100, NX-100S Firmware Ver.2.15 ("Firmware" herein)
is dedicated firmware for TOA's NX-100 or NX-100S Network 
Audio Adapter, and can only be used by upgrading them 
through the network. 
2 models operates by the common firmware Ver.2.00 or laster.
Use these files in a decompressed folder without deleting 
or moving until upgrade completion. 

This ReadMe file contains the following information:
1. Guidance on the License Agreement
2. About this firmware
3. Notes on firmware version upgrade
4. How to upgrade the firmware version
5. How to confirm upgrade completion

1. Guidance on the License Agreement
------------------------------------------- 
You need to consent to the conditions set out in the 
License Agreement when using the Firmware to upgrade the 
NX-100 or NX-100S. Please read the file "license.txt" 
contained in the same decompressed folder before upgrading.

2. About this firmware
------------------------------------------- 
The Firmware is intended for those who are using the NX-100 
, NX-100S firmware of the version earlier than 2.14 and want
to upgrade it.

Version 2.15 differs from version 2.14 in the following 
points:
 *Prevention of the fault that processing that NX-100 stop 
  broadcasting when two or more multicast broadcasting is 
  started and a part of the broadcasting destination is 
  corresponding. 
  
Version 2.14 differs from version 2.13 in the following 
points:
 *Prevention of the fault that NX-100 might reset it 
  automatically when broadcasting for a long time when 20ms 
  delay is set. 

Version 2.13 differs from version 2.12 in the following 
points:
 *Prevention of the fault that audio output become mute for 
  circuit board conforming RoHS 

Version 2.12 differs from version 2.10 in the following 
points:
 *Prevention of the fault that NX-100 becomes impossible to 
  be accessed which might happen when he start of the 
  broadcasting and the broadcasting end control were generated 
  at the same time. 
 *To restore it automatically when CPU abnormality operates, 
  it has improved it. 

Version 2.10 differs from version 2.02 in the following 
points:
 *For RoHS directive conforming new circuit board.
 *Prevention of the fault that NX-100 becomes impossible 
  to be accessed which might happen when the simultaneous 
  broadcasting to plural place by the unicast is stopped.

Version 2.02 differs from version 2.01 in the following 
points:
 *Prevention of the fault that NX-100 becomes impossible 
  to be accessed which might happen when communication 
  error occurs in irrelevant multicast packet to the 
  equipment.
 *Prevention of the fault that NX-100 becomes impossible 
  to stop broadcasting which might happen when start 
  and stop of broadcasting are repeated at high speed.
 *Prevention of the fault that NX-100 comes to repeat 
  release and connection of the TCP session in sereal 
  bridge function(TCP). 
 *Prevention of the fault that NX-100 becomes impossible 
  to be accessed in the following each situation.
    *When access to Web server with long URL. 
    *When a specific TCP port number allocation is set. 
    *When big size configuration file (*.cfg) is uploaded. 
 *Correction of various mistakes in English display of Web 
  server contents. 

Version 2.01 differs from version 2.00 in the following 
point:
 *Prevention of the fault that NX-100 becomes impossible 
  to output audio signal after recovery if packets are 
  continuously lost immediately after broadcast start or 
  before sampling frequency adjustment is completed.

Version 2.00 differs from version 1.22 in the following 
points:
 *Change which corresponds to the selling start of NX-100S
  and makes operation possible by the same firmware. 
 *The addition of clear statement of the warning to 
  failure by the power supply OFF during firmware upgrade. 
 *Prevention of the fault that NX-100 becomes impossible 
  to recognize packet reception or broadcast start becomes
  impossible which happens when broadcasting in the network
  situation that many packets are intermittently received 
  at the speed of 10Mbps or more.
 *Prevention of the fault that serial bridge function etc. 
  becomes impossible (RUN LED blinking), after the 
  communication is completed in an unusual TCP error, when 
  having set the serial bridge function to TCP client.

Version 1.22 differs from version 1.21 in the following 
points:
 *Prevention of the hang-up which happens when the serial 
  bridge function has been used during bi-directional 
  broadcast for a long time (30 minutes or more). 
 *Prevention of the unusual writing of unit setting file 
  which may happen when the packet for sampling frequency 
  correction is received at the moment of uploading unit 
  setting file. 

Version 1.21 differs from version 1.20 in the following 
point:
 *Prevention of the fault that a broadcast start becomes 
  impossible by one broadcast spec. (This broadcast spec 
  is only "Sampling Freq.=32kHz", "Compression=Yes" and 
  "PacketSize=32Byte".)

Version 1.20 differs from version 1.13 in the following 
points:
 *Permits broadcasting destinations to be added or deleted 
  with multiple contact inputs in multicast broadcast. 
 *Outputs a contact input signal to the original NX-100 
  unit's contact output terminal.
 *Outputs Error and Status indicator indications to any 
  desired contact output terminal.
 *Transfers sampling frequency adjustment data by way of 
  IP multicast.
 *Operating log display items added.
 *Outputs stream logs to files.
 *Prevention of communications errors between PC 
  applications, such as operating software, strengthened. 
 *System names and passwords shorter than those preset by 
  factory can be entered.

If you are using firmware of version 2.15 or later, you do 
not need to upgrade the version. The firmware is a file 
"NX100_V215.bin" contained in the same decompressed folder. 

3. Notes on firmware version upgrade
------------------------------------------- 
Make sure that current broadcasts are terminated before 
starting to upgrade. Never switch off the power during 
upgrade or immediately after the power is switched on in 
order to avoid equipment failures. Your upgrade operation 
does by no means adversely affect data settings performed 
for the NX-100 and NX-100S.
To use new functions enabled by the version upgrade, all 
of the NX-100 and NX-100S units in the system must be 
upgraded to the latest firmware. Our latest "NX-100 Software
Ver.2.15" and "NX-100S Installation/Setup Manual," which 
are necessary for the upgrade setting, are made available. 
Please use them by downloading from our product information 
download site (http://www.toa-products.com/international/).

4. How to upgrade the firmware version
------------------------------------------- 
You can upgrade the version with a PC connected to the same 
network as that of the NX-100 and NX-100S, and by using 
either the "NX-100 setup software program (installation
/setting)" or "Browser (installation/setting mode). 
For more information on the method, please read p. 3-29; 
System Settings or p. 4-27; System Management of the 
Installation/Setup Manual. 

5. How to confirm upgrade completion
------------------------------------------- 
The NX-100 and NX-100S operates in Version 2.15 after version
upgrade completion. The following two methods are available 
to check to see if the version has been correctly upgraded: 
(1) If you used the "NX-100 setup software program" to 
    upgrade the version, carry out "Downloading Unit Setting 
    Files" on p. 3-30 of the Installation/Setup Manual 
    after upgrade completion, then ensure that "Firmware 
    version" is "2.15" on the System Setting screen shown on 
    p. 3-29. 
(2) If you used "Browser" to upgrade, restart the program 
    and open the System Management screen on p. 4-27 again 
    from the menu to check to confirm that "Current version" 
    is "2.15."

-------------------------------------------------------------
Copyright (c) 2002-2005 TOA Corporation. All rights reserved.